Marshall Stability Test Apparatus
- Product Type:Marshall Stability Test Apparatus
- Primary Application:Determination of Marshall Stability and Flow of Bituminous Mixtures
The Cone Penetrometer With Digital Timer is a precision laboratory testing instrument used to determine the consistency and penetration characteristics of bituminous materials under controlled test conditions.
The instrument measures the depth to which a standard penetration needle penetrates a prepared bituminous sample under a specified load, temperature, and test duration. The penetration value is used to assess the consistency of bituminous materials and is typically expressed in units of 0.1 mm.
The apparatus is designed for controlled and repeatable testing and can be used in laboratories following established penetration test methods such as ASTM D5, EN 1426, and AASHTO T49.
Bulk pricing available
| Technical Specifications | |
|---|---|
| Product Type | Cone Penetrometer With Digital Timer |
| Primary Application | Determination of Consistency and Penetration of Bituminous Materials |
| Standard Test Load | 100 ± 0.25 g |
| Specialized Test Load | Up to 200 g |
| Standard Penetration Time | 5.0 ± 0.1 seconds |
| Alternative Test Duration | Up to 60 seconds for specific material types |
| Standard Test Temperature | 25°C (77°F) |
| Temperature Tolerance | ±0.1°C |
| Measurement Unit | 0.1 mm |
| Timer | Digital Timer |
| Test Principle | Measurement of Needle Penetration |
| Applicable Standards | ASTM D5, EN 1426, AASHTO T49 |




Essential technical, operational, and standard compliance answers for the Cone Penetrometer With Digital Timer.
It is used to determine the consistency and penetration characteristics of bituminous materials by measuring the depth of penetration of a standard needle under controlled conditions.
The standard penetration test typically uses a total moving weight of 100 ± 0.25 g, including the needle, needle holder, and additional weights.
The standard test duration is 5.0 ± 0.1 seconds. Certain specialized tests may use longer durations, such as 60 seconds.
The primary reference temperature for the penetration test is 25°C (77°F), maintained within a tolerance of approximately ±0.1°C.
The test method is covered by recognized standards including ASTM D5, EN 1426, and AASHTO T49.
The digital timer ensures precise control over the 5.0 ± 0.1 second test duration, providing repeatable penetration measurements and eliminating operator timing error.
We stock tripods, leveling staffs, and protective cases for all our surveying instruments.